Result for method DIAG_CONVNET_2C_FPRED_V2¶
The following figure shows the free-response receiver operating characteristic (FROC) curve of the method.
The overal score of this system is given in the lower right cell of the table below. This is the average sensitivity at an average number of false positives per scan of 1/8, 1/4, 1/2, 1, 2, 4 and 8. The sensitivities at these false positive rates for all nodules and all subsets of nodules are tabulated below.
The following table summarizes the results.
FPs/scan | 0.125 | 0.25 | 0.5 | 1 | 2 | 4 | 8 | Average | |
Sensitivity | 0.669 | 0.760 | 0.831 | 0.892 | 0.923 | 0.944 | 0.960 | 0.854 |